Product description
Requirements
- Manual workstation for EOLT testing for the power battery (compressed string with hydraulic system and magnetic valve in order to maintain the string compressed)
- Measured Master component reference check, right after the control start
- Variable, adjustable input and output cycles, for checking
- Checking the power battery operation (closing time and closing track)
- Inserting the sample backwards, with max. 7 kN
- Cycle duration: max. 3 minutes per sample
- Time for maintaining the sample: 24 hours
- Printer for labels, for editing the IO or NIO labels
- Confirmation of NIO component by the operating staff
- Automatic and manual operation
- Recording in the protocol and archiving of the various process data
Solution
- Testing booth with sample take-over and connection
- Pneumatic fixing unit for the sample
- Sample temperature sensor for temperature compensation
- Pneumatically operated linear unit with sample adapter, to insert the compressed string of the sample
- System for measuring the travel for the sample
- 2 channels security equipment, with protection door monitoring and lock
- Running time measurement
- Separate drawer for stopping time with up to 100 samples
- Printing the NIO labels with error and data code
- Printing the IO labels with company logo, sample name, connection duration, allowable environment temperature, protection type and serial number
- EA Beckhoff system with bus coupler and industrial PC;
- Machine programming with Labview and, simultaneously, evaluation of the measurement results and view on the screen as tables or, optionally, as a diagram presentation
- Archiving the processing data by ODBC interface